Project Description
Special requirements:
- Excellent gating point and surface quality
- Short cycle times
- High repeatability
- Multi-cavity systems
- Clean room compatibilty
- Side gating of parts
- Compact moulds
EWIKON solutions:
Plunger for three-piece disposable syringes
Material: | PP |
Part weight: | 0.35 g |
Mould: | Stack mould |
Hot runner system: | Direct side gating. Linear nozzles, 8 tips |
Cavities: | 48 + 48 |
Two-piece disposable syringes
Material: | PE (plungers) PP (barrels) |
Mould: | 10 moulds for barrels and plungers |
Hot runner system: | Direct side gating. Linear nozzles for plungers, radial nozzles for barrels |
Cavities: | 48, 32, 24 and 16 (depending on the size of the syringe) |
Clot trap with venting adapter
Clot trap | Venting adapter | |
Material: | TPU | SAN |
Part weight: | 0.17 g | 0.45 g |
Hot runner system: | Direct side gating. Radial nozzles | Synchronous plate valve gate system |
Cavities: | 48 | 16 |
Spray head for asthma spray
Material: | HDPE |
Part weight: | 3.5 g |
Hot runner system: | Direct side gating. Linear nozzles |
Cavities: | 16 |
Syringe barrel for dental industry
Material: | Topas (COC) |
Hot runner system: | Direct side gating. Linear nozzles |
Cavities: | 16 |